ASAP Semiconductor

Request an Instant Quote for Part 9975131-6

If you are in need of parts such as 9975131-6 - Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 45.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 250.0 ac all locations from Eaton Corporation, look no further than ASAP Inventory. As a wholly-owned subsidiary of ASAP Semiconductor, we have access to an inventory of more than two billion new and obsolete parts and components such as 9975131-6 and many more. ASAP Inventory is an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a strict No China Sourcing Pledge, helping ensure each part purchased is fully traceable or sourced directly from the manufacturer. Anything not currently in inventory can be sourced and delivered with short lead times and competitive pricing through our international supply chain network spanning North America and Europe.Our website offers parametric search capabilities that allow customers to search for parts through multiple filters, including National Stock Number identification. A National Stock Number is assigned to items repeatedly procured, stocked, issued, and used throughout the federal supply system. ASAP Inventory maintains a broad selection of NSN parts such as 9975131-6 from manufacturers like Eaton Corporation. To begin the purchasing process immediately, submit an RFQ today.

Specifications

Part Number9975131-6
DescriptionPole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 45.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 250.0 ac all locations
ManufacturerEaton Corporation
NSN5925-00-755-4489(5925007554489)
Item NamePole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 45.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 250.0 ac all locations
CAGE Code0AXU3
NIIN00-755-4489(007554489)
FSC Code5925 Circuit Breakers
FSG Code59 Electrical and Electronic Equipment Components
NCB Code00
CountryUSA

Description

Pole Quantity: 3 Maximum Continuous Load Current Rating per Pole: 45.0 amperes ac all locations Operating Voltage Type and Rating per Pole in Volts: 250.0 ac all locations

Request a Quote

22% complete
Part Information
Contact Information
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

If You Have Multiple Parts Requirement, You Can Upload Your Parts List or BOM Here!

NSN Information for Part Number 9975131-6 with NSN 5925-00-755-4489, 5925007554489

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925007554489

Item Description:

CIRCUIT BREAKER

59250075544890P
CIICHCCESDPMICCriticalityENAC
UU
Part NumberISCRNVCRNCCHCCMSDSSADC
9975131-6223

Characteristics Data of NSN 5925-00-755-4489, 5925007554489

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
ADAQBODY LENGTH5.250 INCHES NOMINAL
ADATBODY WIDTH3.000 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH4.359 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.000 INCHES NOMINAL
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.190 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.359 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.000 INCHES NOMINAL
AJECBOSS HEIGHT0.218 INCHES NOMINAL
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE3.312 INCHES NOMINAL
AKPXPOLE QUANTITY3
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE45.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.350 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT AND EXPLOSION RESISTANT
TTQYTERMINAL TYPE AND QUANTITY6 THREADED STUD
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS